Overall Experience
Quality
Price
Convenience
- attempt to pop clog on kitchen line due to current backup. Successfully restored flow with big cable down kitchen cleanout under sink. Cleanup a lil under sink customer stated he’ll get the rest. Tested work with hot water for 5-10min. No warranty on cable
Install light switches, install whole home surge protection
Work inside the panel cannot be done safely until water leaking into the panel has ceased and the internal components are dry. Please call us back after an hvac professional has solved this problem. It appears that the air handler is leaking water into the romex jacket and making its way into the panel. There is corrosion damage to two cables. Ultimately these cables will need to be rerun. Left quote for troubleshoot of living-room circuit and replacing AFCI breaker.